AC Alternator (5)
Diesel Generators (10)
Gas Generators (10)
Inverter Generator (10)
Power Generators (5)Advanced equipments, production line, management present us with great power and production ability. The newest instruments help us to meet all the standards that we need to adopt. Good quality is what we are after. We have the ability to meet the requirements of any OEM.
| Model |
HFG650 |
HFG950 |
HFG1200 |
HFG1500 |
HFG2500 |
||
| Generator |
Phase Number |
Single Phase |
Single Phase |
Three Phase |
|||
| Rated Frequency (Hz) |
50/60 |
50/60 |
50/60 |
||||
| Rated Voltage (V) |
220.110.220/110 |
220.230/110.115.120 |
220/110 |
380/220 |
|||
| Power Factor |
1.0 |
1.0 |
1.0 |
||||
| Rated Output (Kw) |
0.45 |
0.65 |
0.85 |
1.0 |
2.0 |
2.0 |
|
| Maximum AC Output (Kw) |
0.5 |
0.8 |
0.95 |
1.1 |
2.2 |
2.2 |
|
| DC Output in low Voltage |
12V, 8.3A |
12V, 8.3A |
|||||
| Engine |
Engine Model |
1E 45F |
154F |
168F |
|||
| Type |
Forced air-cooled 2-stroke OHV single cylinder |
Forced air-cooled 4-stroke OHV single cylinder |
Forced air-cooled 4-stroke OHV single cylinder |
||||
| Displacement (ml) |
63 |
86 |
163 |
||||
| Maximum Output (HP/rpm) |
2.0HP/3600rpm |
2.4HP/3600rpm |
5.5HP/3600rpm |
||||
| Ignition System |
C.D.I |
Non-contact Transistorized Magneto |
Non-contact Transistorized Magneto |
||||
| Starting System |
Recoil and hand-operated |
Recoil and hand-operated |
Recoil and hand-operated, Electric-operated |
||||
| Fuel Tank Capacity (L) |
4.2 |
5.5 |
15 |
||||
| Fuel Consumption (L/H) |
0.67 |
0.8 |
1.13 |
||||
| Continuous Operating Houses (H) |
6.3 |
6.5 |
13 |
||||
| Engine Oil Capacity (L) |
0.4 |
0.4 |
0.6 |
||||
| Operating Noise at 7m (dB) |
57 |
60 |
65 |
||||
| The Whole |
Dimension L&W&H (mm) |
380&315&330 |
470&380&390 |
600&450&450 |
|||
| N.W / G.W (Kg) |
15/17 |
17.5/19.5 |
20/22 |
24/26 |
43/45 |
||
| 20GP / 40GP |
756/1519 |
360/750 |
230/480 |
||||